Ascorbic acid (vitamin C) can affect or interfere with specific lab results, especially those using hydrogen peroxide or peroxidase, e.g., the Trinder method.
Consumption of peroxide appears to be the predominant mechanism of interference, either inhibiting chromophore production or creating a lag phase in which color does not develop, an effect dependent on the amount of ascorbic acid present. Interference may be minimized by incorporating ascorbic acid inhibiting agents into the test sample or restricting ascorbic acid intake before testing (Martinello 2006).
Besides the ascorbate reduction of hydrogen peroxide or competition with a chromogen, other potential interference mechanisms include electrode interference and cross-reaction with chemicals such as picrate (Meng 2005).
Biomarker |
Effect of Ascorbic Acid on Biomarkers |
Bilirubin, total |
It may increase or decrease serum levels |
Ammonia |
It may decrease serum levels |
Calcium |
It may increase serum levels |
Chloride |
It may decrease serum levels |
Cholesterol, total |
It may decrease serum levels |
Creatinine |
It may increase serum levels |
Glucose |
It may increase serum and capillary levels |
Glycosylated hemoglobin (HbA1c) and fructosamine |
It may decrease serum levels |
Sodium |
It may increase serum levels |
Lactate |
It may decrease serum levels |
Lactate dehydrogenase (LDH) |
It may decrease serum levels |
Potassium |
It may increase serum levels |
Triglycerides |
It may decrease serum levels |
Uric acid |
May increase or decrease serum levels |
Urine tests |
High concentrations of ascorbic acid can lead to false negative results in various urine tests unless using a test known to be resistant to ascorbic acid (Nagel 2006) |
Stool |
Ascorbic acid may cause a false-negative stool occult blood test. |
References Pagana 2022, Katzman 2021, Martinello 2006, Meng 2005, Nah 2016, Vasudevan 2014 |
Ascorbic acid interference may cause an increase or decrease in biomarker values, depending on lab methodology and concentration of ascorbic acid. Some changes are not seen until ascorbic acid reaches very high concentrations that may not be seen under ordinary circumstances.
Food Sources of Select Nutrients, including Vitamin C
Polina Tankilevitch Pexels.com
Research utilizing Beckman Synchron LX20® equipment demonstrated significant interference with specific biomarkers when evaluated with ascorbic acid exceeding 14 mg/dL ( 800 umol/L, 0.8 mmol/L), with some biomarkers becoming non-detectable with ascorbic acid levels of 211 mg/dL (12000 umol/L, 12 mmol/L. Changes at the highest level of ascorbic acid (211 mg/dL), which is excessively high, included (Meng 2005):
Source: Meng, Qing H et al. “Interference of ascorbic acid with chemical analytes.” Annals of clinical biochemistry vol. 42,Pt 6 (2005): 475-7. doi:10.1258/000456305774538274 Convert mmol/L to umol/L https://www.convertunits.com/from/mmol/l/to/umol/l Convert umol/L to mg/dL https://unitslab.com/node/223
Very high ascorbic acid levels may be achieved with intravenous use, including use as an adjuvant to chemotherapy or radiation, where serum levels may reach as high as 17–88 mg/dL (1000–5000 umol/L, 1-5 mmol/L). A significantly falsely elevated glucose result can be observed when checking capillary glucose with glucose oxidase-based strips. Researchers note that serum ascorbic acid levels seen with regular oral use have not been shown to interfere with capillary glucose monitoring, e.g., 1.55-3.1 mg/dL (88-176 umol/L, 0.88-0.176 mmol/L) (Vasudevan 2014).
Katzman, Brooke M et al. “Unintended Consequence of High-Dose Vitamin C Therapy for an Oncology Patient: Evaluation of Ascorbic Acid Interference With Three Hospital-Use Glucose Meters.” Journal of diabetes science and technology vol. 15,4 (2021): 897-900. doi:10.1177/1932296820932186
Martinello, Flávia, and Edson Luiz da Silva. “Mechanism of ascorbic acid interference in biochemical tests that use peroxide and peroxidase to generate chromophore.” Clinica chimica acta; international journal of clinical chemistry vol. 373,1-2 (2006): 108-16. doi:10.1016/j.cca.2006.05.012
Meng, Qing H et al. “Interference of ascorbic acid with chemical analytes.” Annals of clinical biochemistry vol. 42,Pt 6 (2005): 475-7. doi:10.1258/000456305774538274
Nagel, Dietmar et al. “Investigations of ascorbic acid interference in urine test strips.” Clinical laboratory vol. 52,3-4 (2006): 149-53.
Nah, Hyunjin et al. “Ascorbate Oxidase Minimizes Interference by High-Concentration Ascorbic Acid in Total Cholesterol Assays.” Annals of laboratory medicine vol. 36,2 (2016): 188-90. doi:10.3343/alm.2016.36.2.188
Pagana, Kathleen Deska, et al. Mosby's Diagnostic and Laboratory Test Reference. 16th ed., Mosby, 2022.
Vasudevan, Sumangala, and Irl B Hirsch. “Interference of intravenous vitamin C with blood glucose testing.” Diabetes care vol. 37,5 (2014): e93-4. doi:10.2337/dc13-2452